SETTINGS
6 720 806 768 (2013/02)48
20.2 HOT WATER
Under Hot water, there are functions to:
Acknowledge hot water sensor T3
Extra hot water
Hot water peak
Hot water program
Hot water mode
Hot water settings heat pump x
Block heating during hot water demand
Maximum operating time for hot water at heating demand
Hot water circulation
Protective anode installed
> Acknowledge hot water sensor T3
> Extra hot water
>> Extra hot water duration
Set the duration of extra hot water production.
>> Extra hot water stop temperature
Set the stop temperature for extra hot water.
Additional amount of hot water is produced by temporarily increasing
the temperature of the hot water during the set number of hours to the
indicated stop temperature.
The heat pump starts the function directly and uses the compressor first
and then the additional heat source to increase the temperature. When
the desired number of hours have passed, the heat pump returns to
normal hot water mode.
> Hot water peak
Hot water peak means a temporary increase in the hot water
temperature to approx. 65 °C for thermal elimination of bacteria
(pasteurisation).
The Hot water circulation pump is controlled by the control unit during
the hot water peak.
For the hot water temperature increase, the compressor is used first;
the additional heat source then continues alone.
>> Day of the week
Set the day on which the hot water peak should take place. None
means that the function is disabled. All means that a hot water peak
takes place every day.
If hot water peak is deactivated comfort mode must be selected in the
menu hot water mode.
▶Select None if electric additional heat in the hot water cylinder is
installed and controlled by external sources.
>> Interval in weeks
Set how often a hot water peak should take place.
1 means a hot water peak every week.
2 means that a hot water peak takes place in all even weeks of the
year, i.e. in week 2, 4, 6, etc.
3 means week 3, 6, 9, etc.
4 means week 4, 8, 12, etc.
>> Start time
Set the time of the hot water peak.
>> Maximum time
>> Time for warm-keeping (Duration of hot water peak)
▶Set Maximum time and Time for warm-keeping (Duration of hot
water peak).
The hot water peak is activated on the selected day and at the selected
time. It continues until the stop temperature has been reached plus
the time for warm-keeping (duration of hot water peak). The hot water
peak cannot continue longer than the set Maximum time. If it is
cancelled because the maximum time has expired, a message is
shown in the display and a new attempt is made after 24 hours.
> Hot water program
Program 1 and Program 2 enables you to block hot water production
during the set time.
>> Active program
>> View/edit active program
The menu is displayed only if Program 1 or Program 2 has been
selected. Programs are changed in the same way as for Room
temperature program (Chapter 20.1).
> Hot water mode
Factory setting Yes (if correctly installed)
Alternative Yes/No
Table 79 Acknowledge hot water sensor
Factory setting 0h
Lowest value 0h
Highest value 48h
Table 80 Extra hot water duration
Factory setting 65 °C
Lowest value 50 °C
Highest value 65 °C
Table 81 Extra hot water stop temperature
DANGER: Risk of burn injuries.
Use a mixing valve when the hot water temperature
exceeds 60 °C.
Factory setting Wednesday
Area None, Day, All
Table 82 Weekday
Factory setting 1
Lowest value 1
Highest value 4
Table 83 Week interval
Factory setting 3:00
Lowest value 0:00
Highest value 23:00
Table 84 Start time
Factory setting 3.0h
Lowest value 1.0h
Highest value 5.0h
Table 85 Maximum time
Factory setting 1.0h
Lowest value 1.0h
Highest value Maximum time - 1h
Table 86 Time for warm-keeping
Factory setting Always hot water
Alternative Always hot water
•Program 1
•Program 2
Table 87 Hot water program
Factory setting Economy
Alternative Economy/Comfort
Table 88 Hot water mode