MPH-02, MPB-02, MPD-02 Extended Drive Functions 9-29
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
2 assignment mechanisms for analog inputs
(assignment A or B)
different sampling rates of assignments A and B
assignment channel A works in position loop clock
(advanced: T = 250µs, basic: T = 500µs)
assignment channel B works in 2-ms-clock
assignment to command value/limit value/control parameters of the
drive by means of adjustable scaling
possible assignment of only max. 2 analog inputs to internal drive
parameters
variable scaling for 2 analog channels
dead zone to be entered for suppressing the zero drift for both analog
channels
offset and amplification adjust for both analog channels via command
Analog Inputs on the Control Module
Properties of the analog inputs (or input) on the control module:
number of analog inputs depending on hardware or control section:
advanced: 1 analog input with 12 bits
basic: basic 4 has 2 analog inputs with 12 bits
(other basic types don't have analog inputs)
double-axis: 1 analog input with 12 bits shared by both axes. The
input can, however, be used by both axes at the
same time!
8-fold oversampling for both analog channels
low-pass filtering to be activated for both analog channels
analog inputs designed as differential input
input voltage range of ±10 V
Analog Inputs 3 and 4 on Optional Module MA1
The optional module MA1 was developed according to VDE 0411-
part 500 (programmable logic controllers) and should be used according
to the specifications contained in this standard.
Properties of the analog inputs on the optional module MA1:
2 analog inputs with 12 bits
8-fold oversampling for both analog channels
low-pass filtering to be activated for both analog channels
analog inputs designed as differential input
input voltage range of ±10 V
connection via 15-pin D-Sub connector
Pertinent Parameters
P-0-0210, Analog input 1
P-0-0212, Analog input, list of assignable parameters
P-0-0217, Analog input 1, time constant input filter
P-0-0218, Analog input, control parameter
P-0-0219, Analog input, maximum value for adjust
P-0-0220, C2800 Analog input adjust command
General Features