1-26 System Overview MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Firmware type →
FWA-INDRV*-MPB-
02VRS
(Basic single-axis)
FWA-INDRV*-MPD-
02VRS
(Basic double-axis)
FWA-INDRV*-MPH-
02VRS
(Advanced single-axis)
Functions of the base
packages
without
encoder
(open-loop)
with encoder
(closed-loop)
without
encoder
(open-loop)
with encoder
(closed-loop)
without
encoder
(open-loop)
with encoder
(closed-loop)
torque/force control X X X
velocity control X X X X X X
position control X X X
drive-internal interpolation X X X
drive-controlled positioning X X X
Operating
modes
positioning block mode X X X
Drive Halt XXXXXX
travel range limit switch X X XXXX
position limit values
software limit switch)
XXX
detecting marker position X X X
positive stop drive procedure X X XXXX
drive-controlled homing X X X
Drive
functions
setting absolute measuring X X X
E-Stop function X X X X X X
torque disable X X X X X X
v
cmd
set to zero
("emergency halt")
X X X X X X
Error
reactions
v
cmd
set to zero with ramp and
filter ("quick stop")
X X X X X X
analog I/Os (on basic device or
optional module)
X
1)
X
1)
X
1)
X
1)
X
1)
X
1)
digital I/Os (on basic device or
optional module)
X
1)5)
X
1)5)
X
1)5)
X
1)5)
X
1)
X
1)
encoder emulation X
1)
X
1)
X
1)
Expanded
drive
functions
position switch points X X X
MMC support X
3)
X
3)
X X X X
firmware handling X X X X X X
standard control panel X X X X X X
scaling/standardization X X X X X X
option. parameteriz. interface X X X X X X
oscilloscope feature X X X X X X
Handling,
diagnosis,
service
patch function X X X X X X
1) depending on hardware configuration
2) max. 24 byte MDT/AT data per axis and min. Tscyc = 1000 µs
3) only with control section "BASIC UNIVERSAL"
4) brake check and brake abrasion not possible
5) no digital I/Os on optional module for basic design
Fig. 1-8: Scope of functions of the basic firmware packages (continuation)