6-10 Drive Control MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
The activation of the stall protection loop is displayed in parameter
P-0-0046, Status word of current controller (bit 12: stall protection
loop):
bit 12 = 1 stall protection loop active
In addition, the diagnostic message E8040 Torque/force actual value
limit active is generated.
bit 12 = 0 stall protection loop not active
The activation of the current limitation loop is displayed in parameter
P-0-0046, Status word of current controller (bit 13: current limitation
loop):
bit 13 = 1 current limitation loop active
In addition, the diagnostic message E8041 Current limit active is
generated.
bit 13 = 0 current limitation loop not active
The status of the velocity search mode can be read in parameter
P-0-0046, Status word of current controller (bit 14: search mode):
bit 14 = 1 search mode active
bit 14 = 0 search mode not active
Field-Oriented Closed-Loop Current Control
Brief Description
The drive function "field-oriented current control" is made available in the
base package "closed-loop".
Note: The current loop was preset for all Rexroth motors and
normally does not have to be adjusted.
For notes on how to commission the current loop for third-
party motors see "Third-Party Motors" in chapter "Motor,
Mechanical Axis System, Measuring Systems"!
In the case of field-oriented closed-loop current control, the internal
control task consists in generating the transformed currents I
d
and I
q
in
closed-loop-controlled form:
I
d
(field-generating current) PI loop for I
d
I
q
(torque-generating current) PI loop for I
q
With the firmware, you can operate asynchronous and synchronous
motors in the entire speed range, including field weakening.
As a basic principle, we distinguish the following three working ranges:
base speed range (1) constant torque
field weakening range (2) constant power
field weakening range (3) power limit range
Status of Stall Protection Loop
Status of Current Limitation
Loop
Status of Velocity Search Mode
Working Ranges
Base package of all variants in closed-loop characteristic