Bosch LTC 8500 Manuel d'instructions Page 44

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 104
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 43
EN | 34 Bosch Security Systems | December 13, 2005
•Switch 5 of S1001
In the ON position, this switch is used to force the CPU into a “boot” mode so it
is ready to accept a download of an operating system program via its console
port. This setting should not be changed unless a problem has been encoun-
tered while attempting to download a new operating system program.
•Switch 6 of S1001
This switch selects the handshake setting of the console port when switch 5
(described above) is in the ON position. When ON, the handshake is enabled
(recommended position).
•Switch 7 and Switch 8 of S1001
These switches are used to set the baud rate when downloading a new operating
system program. It is recommended to use the fastest rate possible.
Lower CPU DIP Switch S1002
The lower DIP switch provides several user-selectable options. These options are as
follows:
•Switch 1 of S1002
This switch is not used in these systems and should be left OFF.
•Switch 2 of S1002
This switch allows the alarm port on the rear of the main Allegiant bay to con-
figure as an auxiliary console port when switch 2 is turned ON. This auxiliary
port allows the alarm port (in addition to the regular console port) to communi-
cate with the optional LTC 8059/00 MCS package or the optional LTC 8850/00
GUI Software package.
The port can also be used to control the Allegiant system via the Console Com-
mand Language (documented in the optional CCL manual). The normal con-
sole port and the alarm port (when switch 2 is ON) may be used to control the
Allegiant system simultaneously. Communications parameters (baud & hand-
shake) for the alarm port can be set using the keyboard (see User Function 32),
with the optional LTC 8059/00 MCS package or with the optional
LTC 8850/00 GUI Software package.
Switch Switch Baud
7 8 Rate
OFF OFF 38400
OFF OFF 19200
ON OFF 9600
ON OFF OFF 1200
DIP Switch
Number
Factory Default
Setting
“Lower”
S1002 DIP Switch Function
1OFFReserved
2OFFAlarm Port Mode
3OFFOld Keyboard Modes
4OFFPrinter Port Mode
5ON Security Feature
6OFFNot Used
7ON Keyboard Protocol Mode
8ON Communication Parameters