48 en | Configuration using a Web browser VideoJet XTC XF
DOC | V5.60 | 2012.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH
5.19 Network > Advanced
The settings on this page are used to implement advanced settings for the network.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes
to Set and Reboot.
1. Make the desired changes.
2. Click the Set and Reboot button. The unit is rebooted and the changed settings are
activated.
SNMP
The VideoJet XTC XF transcoder supports the SNMP V2 (Simple Network Management
Protocol) for managing and monitoring network components, and can send SNMP messages
(traps) to IP addresses. The unit supports SNMP MIB II in the unified code. If you wish to send
SNMP traps, enter the IP addresses of one or two required target devices here.
If you select On for the SNMP parameter and do not enter an SNMP host address, the unit
does not send the SNMP traps automatically, but only replies to SNMP requests. If you enter
one or two SNMP host addresses, SNMP traps are sent automatically. Select Off to deactivate
the SNMP function.