42 en | Configuration using a Web browser VideoJet XTC XF
DOC | V5.60 | 2012.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH
You can select different events that automatically activate an output. It is possible, for
example, to turn on a floodlight by triggering a motion alarm and then turning the light off
again when the alarm has stopped.
Idle state
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is
to operate as an NC contact.
Operating mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select
Bistable. If you wish an alarm-activated siren to sound only for a defined period, for example,
select the corresponding setting.
Relay follows
Select the event that triggers the relay.
Relay name
You can assign a name for the relay here. The name is shown on the button next to Trigger
relay. If the LIVEPAGE functions are configured accordingly, this name is displayed below the
relay icon. You can also use the name in the Forensic Search program function as a filter
option for quick search in recordings. Enter a unique and clear name here.
Further topics:
Section 5.7 Web Interface > LIVEPAGE Functions, page 29
Trigger relay
Click the button to trigger the relay manually (for testing or to operate a door opener, for
example).
5.17 Interfaces > COM1
You can configure the serial interface parameters (orange terminal block) to meet your
requirements.
CAUTION!
Do not use any special characters, for example &, in the name.
Special characters are not supported by the system's internal management.