1. When the fault is reset, send the restored report to the configured destinations.
– Battery Low Battery
Condition:
1. Battery voltage is lower than 11V+-1%.
2. No battery connected.
Restore:
When Battery voltage rises to 12V+-1%, Dynamic Battery test is performed (time set in
Programming address 204) and fault is reset.
Supervise:
1. The system performs a Dynamic Battery Test every time (set in address 204) and every time
the system is armed or reset.
2. Report the low battery to the configured destination programmed on address 124.
3. Slow flash FAULT indicator (refer the detailed description in chapter keypad indicators)
4. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
– Panel Aux Power Failure
Condition:
Aux Power Supply Voltage is lower than 9V.
Restore:
Voltage is raised to 12 and fault is reset.
Supervise:
1. Monitor the voltage by MPU.
2. Report the AUX power fault to the configured destination programmed on address 124.
3. Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
4. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
– Bosch Option Bus Power Failure
Condition:
Bosch option bus power supply Voltage is lower than 9V+-5%.
Restore:
Voltage is raised to 12V and fault is reset.
Supervise:
1. Monitor the voltage by MPU.
2. Report the Bosch Option Bus Power Supply fault to the configured destination
programmed on address 124.
3. Slow flash FAULT indicator (refer to the detailed description in chapter keypad
indicators)
4. When the fault is reset, send the restored report to the configured destinations. The
FAULT indicator is turned off when there is no other system fault.
– RF Repeater AC Power Failure
No description defined
– RF Repeater Battery Failure
No description defined
– RF Sensor Power Failure
No description defined
AMAX panel 4000 / AMAX panel 4000