Vue de la page 13
Y
G
B
R
AUX 2+
AUX 2-
AUX 1-
AUX
1+
R
B
G
Y
DX2010
Yellow
Green
Black (-)
Red (+)
Alarm Control Panel
TMPR
1
COM
Figure 5.3: Connecting DX2010 to the Control Panel
For use of external power supply, refer to Figure below.
Figure 5.4: Connecting DX2010 to the Control Panel with External Power supply
Notice!
The alarm control panel provides 12 VDC power supply with maximum 900mA for each bus or
auxiliary power for the output of external devices.
When the total current of the bus and the auxiliary power supply exceeds 2A, an external
power supply is required.