Bosch AMAX panel 4000 EN Guide d'installation Page 50

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 176
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 49
If there are two or more zones programmed as delay zones and both are triggered,
the follower zone will follow the first triggered delay zone
3. STAY ARM: same as the delay zone.
6 - Interior Follower
The interior follower zone will perform as below:
1. Disarm: same as the Instant Zone disarm status
2. AWAY Arm: same as the Follower Zone AWAY Arm status
3. STAY Arm:
This zone will be ignored and performed as disarm.
Refer to Section Keypad Indicators, page 20 to see how the zone is displayed during
exit time.
7 - 24 Hour Zone
The 24 Hour zone will perform as below:
1. Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
2. AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
3. STAY Arm: Same as AWAY Arm performance.
A 24 Hour zone does not send a restore report until the zone is restored.
8 - Tamper Zone
The Tamper zone will perform as below:
1. Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
2. AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
3. STAY Arm: Same as AWAY Arm performance.
A Tamper zone does not send a restore report until the zone is restored.
9 - Fire Zone
The Fire zone will perform as below:
1. Disarm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
2. AWAY Arm:
Zone normal - no Alarm / no report
Zone triggered - Alarm / report
Zone triggered - during exit time - Alarm / report
Zone triggered - during entry time - Alarm / report
3. STAY Arm: Same as AWAY Arm performance.
50
en | Settings
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH
Vue de la page 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 175 176

Commentaires sur ces manuels

Pas de commentaire