c) To exit from Fault and Tamper Analysis Mode, press [#].
System Test
Siren Test
This function allows the code holders to test the siren.
a) Enter your Code + [4] [1] and press [#]. It beeps twice and the siren will be activated for 1
second.
Communication Test
This function allows the code holders to send a test report to a central monitoring station.
a) Enter your Code + [4] [2] and press [#]. It beeps twice and a test report is send.
The Keypad will display the status of the test report for all communication paths.
To exit the test report press [#].
Walk Test Mode
This function allows code holders to test detection devices to ensure they are functioning
correctly. Before activating Walk test Mode, bypass any zones that are not required for testing.
During the walk test, no walk test report is sent out to the control panel system.
How to enter into Walk Test Mode:
1. Enter your Code + [4] [3] and press [#]. It beeps twice and the STAY and AWAY indicators
flash.
2. Unseal and seal the zones to be tested. The keypad sounds one second beep and the
siren sounds one beep each time when a Zone status is changed.
To exit Walk test Mode:
1. Enter your Code + [4] [3] and press [#].
Event Log Recall Mode
This function allows code holders to playback the last 254 events saved in each event log on
the Text Keypad.
All Event Log here all events are logged
EN Event Log here only EN related events are logged
Dialer Event Log here only Dialer related events are logged
How to enter Event Log Recall modes:
All Event Log
Enter your code + [2] [2] and press[#]. It beeps twice.
EN Event Log
Enter your code + [2] [3] and press [#]. It beeps twice.
10.4
10.4.1
10.4.2
10.4.3
10.5
162 en | Keypad Usage and Operations
AMAX panel 4000 / AMAX panel 4000
EN