DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 40
Bosch Security Systems | 8/04 | 4998153891C
Opening/Closing Report Routing
Address: 0262
Default: 1 (Reports to Destination 1, Events to Log/Printer)
Selections:
0 = No Reports, no Events to Log/Printer
1 = Reports to Destination 1, Events to Log/Printer
2 = Reports to Destination 2, Events to Log/Printer
3 = Reports to Destinations 1 & 2, Events to Log/Printer
4 = Reports to Destination 2 only on Destination 1 Comm Fail Event, Events to Log/Printer
5 = No reports, Events to Log/Printer
This is a global parameter that affects all zones, all areas, and all PINs.
The Exit Error {18} and Recent Closing {19 to 20} reports follow alarm routing. See “Communication Failure
(Comm Fail)” for a description of a Comm Fail event and “Dialing Attempt Tables” for a description of the
dialing sequence in the DS7200V2 Installer’s Guide (P/N: 4998153893).
Enable reporting at the Global Reporting Options parameter (see Global Reporting Options on page
19), and enter at least one phone number (or IP address) for one routing destination (see Phone
Number 1 (2) for Destination 1 (2) on page 9).
Exit Time Restart
Address: 0263
Default: 1 (Exit Time Restart)
Selections:
0 = No Exit Time Restart
1 = Exit Time Restart
If Exit Time Restart is set to Restart (1), a violation, restoral, and second violation of an Entry/Exit Delay zone
(before the end of Exit Delay) restarts Exit Delay. One restart is allowed per arming cycle. A violation, restoral,
and second violation must all occur at the same Entry/Exit zone.