Bosch Alarm Panel Interface Manual
Revision 1.4
8.3.5 How to see and manage the IP connections between services
The TCP/IP Connections tab shows the incoming and outgoing IP connections between GCS Services.
The ClientGW Service and the DBWriter Service should each show a connection in this screen. There
should only be one Client Gateway connection even if the system has more than one client.
FIG 12: Alarm Panel Service screen/Connecting to the DBWriter (cropped)
Right-click the panel status and
Select the desired command
User can manually connect and disconnect from the services by right-clicking the TCP/IP Service
Connections screen and getting a shortcut menu.
` Force Disconnect option: allows operator to manually disconnect the selected service.
ª The incoming (ClientGW) service should reconnect automatically within 30 to 60 seconds
provided it is up and running.
ª The outgoing connection to DB Writer Service can be forced to reconnect using the ‘Connect
to Server’ option on the shortcut menu.
` Connect To Server option: allows the user to manually connect to the downstream service (in this
case the DBWriter). To reconnect manually, you must know the IP address and port number of the
downstream service. DBWriter listens on port 4001. Use the NIC card loop-back address (127.0.0.1)
if the DBWriter and Alarm Panel service are both running on the same computer (which should be
the case).
4001
Page 28 of 37