Vue de la page 13
Bosch Alarm Panel Interface Manual
Revision 1.4
Additional Utilities explained on this page …
Also in the Alarm Panel Property screen are remote configuration options for the alarm panel.
These are utility features that allow the operator to send commands or data to the selected Alarm
Panel.
Virtual Keypad = allows operator to mimic typing at
the Bosch keypad. Allows up to 8 keypads. Allows
operator to interface with the Bosch Alarm panel
from System Galaxy.
To use the virtual keypad, do the following:
1. set the keypad number you wish to mimic
2. type in the desired code
3. click the [#] button
4. click the [send] button to send the code to the
alarm panel
FIG 5b: Virtual Keypad dialog
Set Poll Rate – allows operator to set the poll rate
between the alarm panel and SG (in 10
th’s
of
seconds)
o 0 = OFF; don’t send any status
o 5 = send status every 0.5 sec
o 10 = send status every 1.0 sec
o 15 = send status every 1.5 sec
FIG 5c: Poll Rate dialog
Set User Code – the system allows up to 249 user
codes (per alarm panel specification). Using this
feature can overwrite an existing code at the
alarm panel if the operator chooses a number
that is already in use.
If a user code is sent from
this utility it is not stored in the SG database.
FIG 5d: User Code dialog
Set Key Pad Text allows operator to send 16-
character text message to the Bosch keypad display.
NOTE: this message will show on all keypads
FIG 5e: Set Keypad Text dialog