- 32 -
This chart explains the procedure for performing a Zone Test.
It is recommended that the system be tested weekly.
The Zone Test is used to confirm that detectors will report alarms to the keypad.
A Zone Test works on all zones, except 24-hour zones and fire zones.
While the keypad is in a Zone Test, no control panel alarms will activate an alarm, except 24-hour zone alarms and fire alarms;
these will override the Zone Test function.
* = If this test is performed from a Master keypad, it must be in Single Partition Mode.
Testing your System
What will Happen
Command
Sequence
[PIN] + [#] [8] [1]
T
pe of
Test
“Test Zone”
will displa
on the DS7447 followed b
the zone number of an
zones that have not been
tested.
The DS7445 will flash the zone LEDs of an
untested
zones.
“Now Testin
”
will displa
on the DS7447 followed b
the zone number of the zone that is currentl
bein
violated (tested). It returns to
“Test Zone”
after the
violation.
The DS7445 will turn the zone LED on stead
for the
zone that is currentl
bein
violated (tested).
Zone Test
What to Do
Test each detector one at a
time as instructed b
the
installin
compan
.
To exit the Zone Test mode,
enter
our [PIN] followed b
the [#] ke
.
Commentaires sur ces manuels