Vue de la page 44
AMC2 4W | Installation manual Installing | en 45
Bosch Sicherheitssysteme GmbH F.01U.024.965 | V 0.1 | 2006.03
Fig. 5.20 Wet mode and dry mode of the AMC2 4W relay outputs
Maximum switching power of each relay output is 60 VA, maxi-
mum switching voltage 30 V DC and maximum switching cur-
rent 2 A.
Risk of Damage!
Do not connect externally powered devices in wet mode This
can damage the AMC2 4W
Risk of Damage!
Do not exceed switching specifications of the relay. Using
exceeding voltage or current on relay contacts in either mode
can damage the AMC-W.
i
NOTE!
A complete connection diagram of the relay output connectors
is shown in chapter Section 7.1 Connecting Diagrams of this
documentation.