AMC2 4W | Installation manual Installing | en 37
Bosch Sicherheitssysteme GmbH F.01U.024.965 | V 0.1 | 2006.03
5.6.3 DIL Switch Address Selector
The first four DIL switches for address selection define the RS-
485 address of the AMC2 4W in a RS-485 bus system. Switch 5
selects on of the two different protocols, SDEB and BPA
(according to DIN6619). Switch 6 sets the connection to the
host system to either RS-232 or RS-485.
Fig. 5.13 Location of the RS-485 address selector
i
NOTE!
Using Ethernet connection it is recommended to set switch 1 to
ON (= delivery status)
Using RS-232 connection the address must be set, which is con-
figured in the Device Editor. Therefore this is a point-to-point
connection the usually configured address will be 1 - so the
switch 1 must be also set to ON.