How to use the MegaCLI Command-Line Utility
Use a bootable DOS USB stick with XMS manager "himem.sys" and start the MegaCLI.exe.
Please see the command reference in MegaCLI Commandline Utility, page 47.
The whole amount of log events can be seen with MegaCLI –AdpAliLog –aAll > evt.txt; but it
takes a few minutes until the large file is written and it is too much information.
For example, it is much better, to use this commands
(create with "-f …txt" a file for analysis)
MegaCli -AdpEventLog -GetEvents -warning -f warning.txt -aALL
Adapter: 0 - Number of Events : 288
seqNum: 0x00001875
Time: Mon Jul 19 13:37:28 2010
Code: 0x00000124
Class: 1
Locale: 0x20
Event Description: Patrol Read can't be started, as PDs are either not ONLINE, or are in a VD
with an active process, or are in an excluded VD
Event Data:
===========
None
seqNum: 0x0000188b
Time: Mon Jul 19 13:52:41 2010
Code: 0x00000070
Class: 1
Locale: 0x02
Event Description: Removed: PD 06(e0xfc/s6)
Event Data:
===========
Device ID: 6
Enclosure Index: 252
Slot Number: 6
MegaCli -AdpEventLog -GetEvents -critical -f critical.txt -aALL
Adapter: 0 - Number of Events : 288