1. MAP Panel Enclosure Kit (ICP‑MAP0110)
2. MAP 5000 Main Panel (ICP‑MAP5000)
Supports wired inputs, tamper input, power drive outputs, dry
contact outputs, power supply input, auxiliary power output, bus
connectors, installer button, and Ethernet jack.
3. MAP DE Module (ICP‑MAP0007)
Supports AT 2000 Communicator and DR2020 Printer
connectivity, provides three fully supervised and programmable
outputs (intended for sirens, strobes, and other local notification
devices), and provides two open‑collector outputs.
4. AT 2000 Communicator
5. DR2020 Printer
6. Sirens, Strobes, and Local Notification Devices
7. MAP LSN Gateways (ICP‑MAP0010)
The Modular Alarm Platform 5000 solution supports a maximum
of eight gateways. Each gateway supports one loop or two stub
configurations.
8. MAP Power Supply 150W (IPP‑MAP0005)
This is the local power supply for the MAP 5000 Main Panel. It
has two individually supervised battery circuits, each capable of
supporting 24 V, 40 Ah. Additional remote power supplies can
be placed on the external Bosch Data Bus (BDB).
9. Batteries
The MAP Panel Enclosure Kit (ICP‑MAP0110 ) houses either:
two 12 VDC, 40 Ah batteries in series on one of the two
battery circuits, or
four 12 VDC, 18 Ah batteries with two batteries in series
on each of the battery circuits.
10
.
Internal Bosch Data Bus (BDB)
This is the internal backbone of the modular system, providing
interoperability between the various MAP modules. It is limited
to 6 m (19.5 ft) in total length.
11
.
External Bosch Data Bus (BDB)
This bus spans across the premises to connect control centers,
LSN Gateways, and supervised remote power supplies. It can be
up to 1000 m (3280 ft) in total length.
12
.
MAP Control Center (IUI‑MAP0001)
Up to 32 control centers.
13
.
Ethernet Connection
This allows the MAP system to connect to a management system
such as the Bosch Building Integration System (BIS) and to
programming software such as the Bosch Remote Programming
Software (RPS).
Functions
Arming and Disarming
Users can arm or disarm the system using Bosch
SmartKey systems. The number of SmartKey users is
limited by the specific SmartKey devices up to a MAP
system maximum of 996 SmartKey users.
Users can also arm or disarm the system using the
MAP Control Center (IUI‑MAP0001). For each user, a
preferred language (English or German) is selected.
When the user logs in, the preferred language is used
at the control center. The MAP system supports up to
32 control centers and up to 1000 users.
Addresses
The MAP system supports up to 1500 addresses. An
address represents a single input, single output, or a
single tamper input. Any combination of inputs,
outputs, and tamper inputs can be used to realize the
maximum number of 1500 addresses system wide.
Notice
Bosch Data Bus devices do not count toward the
1500 available addresses.
Bosch Data Buses with CAN Technology
The MAP system uses two data buses which have CAN
technology and are used to connect devices to the
MAP 5000 Main Panel (ICP‑MAP5000). The first BDB,
which can be up to 6 m (19.5 ft) in length from the
main panel, is the internal backbone of the modular
system, providing interoperability between the various
MAP modules. A second, isolated BDB, which can be
up to 1000 m (3280 ft) in length from the main panel,
is the external bus, spanning across the premises to
connect control centers and supervised remote power
supplies.
Firmware Upgrades
The firmware of all devices in the MAP system can be
upgraded or updated with the Bosch Remote
Programming Software (RPS). This allows for on‑site
or off‑site (IP through Ethernet) upgrades or updates.