Bosch D7412GV2 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Systèmes de contrôle d'accès de sécurité Bosch D7412GV2. D7412GV2 Control Panel Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 6
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Intrusion Systems | D7412GV2 Control Panel
The D7412GV2 Control Panel provides an integrated
solution for intrusion, access control, and fire alarm
system applications. Monitor alarm points for intruder
or fire alarms while operating user keypads and other
outputs. The D7412GV2 Control Panel includes a
communicator that sends event reports to selected
public switched telephone network (PSTN) or IP
network destinations through four programmable route
groups. Program all system functions on-site through a
D5200 Programmer or remotely through Remote
Programming Software (RPS).
Add up to two doors of access control using the optional
D9210BLC Access Control Interface Module.
The D7412GV2 Control Panel provides up to 75
individually identified points. Each point accommodates
normally-open (NO) and normally-closed (NC) devices
with end-of-line (EOL) resistor supervision. Each point
is programmable for fire, fire supervisory, or intrusion
applications.
Functions
Programmable Outputs
2 A alarm power at 12 VDC
1.4 A auxiliary power at 12 VDC
Four alarm output patterns
Automatic bell test
Programmable bell shut-off timer
System Response
31 custom point indexes, including fire supervisory
Selectable point response time
Cross point capability
Fire alarm verification
Fire inspector’s local test
Watch mode
Scheduled events (skeds) arm, disarm, bypass and
unbypass points, control relays, control authority
levels, and control door access
User Interface
Supervises up to eight keypads (up to 32 non-
supervised command centers can be used)
Custom keypad text
Full function command menu including custom
functions
Each user has authority by area and 16-character
name
D7412GV2 Control Panel
Fully integrated intrusion, fire, and access control
allows users to interface with one system instead of
three
NetCom IP based communication option provides
high-speed, secure alarm transport and control
Eight programmable areas with perimeter and interior
partitioning
75 points with flexible configuration options to meet
multiple installation requirements
Your choice of vacuum fluorescent or ATM style user
interface keypads
New user interface functions provide additional
security and flexibility
Up to 67 RF points
www.boschsecurity.com
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - D7412GV2 Control Panel

Intrusion Systems | D7412GV2 Control PanelThe D7412GV2 Control Panel provides an integratedsolution for intrusion, access control, and fire alarmsyste

Page 2 - 2

2 | D7412GV2 Control Panel•14 custom authority levels control user’s authority tochange, add, delete passcodes, delete access controltokens, delete c

Page 3 - D7412GV2 Control Panel

D7412GV2 Control Panel | 3keypad or remotely retrieve event information usingRPS. RPS operators can retrieve events periodicallyusing one phone call,

Page 4 - 4

4 | D7412GV2 Control PanelD129 Class A Initiating ModuleD130 Auxiliary Relay ModuleD185 Reverse Polarity Signaling ModuleD192C Notification Appliance

Page 5 - D7412GV2 Control Panel

D7412GV2 Control Panel | 5Technical SpecificationsCommunicationsSDI Bus A (+): 9 VDC4572 m (15,000 ft)SDI Bus B (-): 9 VDC4572 m (15,000 ft)Telephone

Page 6 - 6

6 | D7412GV2 Control PanelOrdering InformationD138 Mounting Bracket, Right AngleUsed to mount accessory modules in D8103, D8108A, and D8109 enclo-sur

Commentaires sur ces manuels

Pas de commentaire