D9412GV3/D7412GV3 | Operation and Installation Guide | Appendix A: System Wiring Diagrams, Issue A
.
Bosch Security Systems, Inc. | 2/10 | F01U143070-01 71
Figure 38: D7412GV3, Input Points and Peripheral Devices
Sw. Aux Pwr
Zone B
Zone A
Pnl Common
Pnl Common
Loo p B-
Loo p A-
L oop B +
L oop A+
Earth Ground
10
9
5
4
3
8
2
1
7
6
Aux Pow er
Zo ne B
Zo ne A
Comm on
Lo op B-
Lo op A-
Loop B+
Loop A+
Eart h Grou nd
10
9
5
4
3
8
2
1
7
6
11
12
13
Loop A+
Lo op A-
Loop B+
Lo op B-
+-
Point 5 P oint 6
1817 19
Point 7 Point 8
2120 22
VOLTAG E RANGES
Op e n 3.7 - 5.0 VDC Short 0.0 - 1.3 VD C
Norm a l 2.0 - 3.0 VDC
D7412GV3
EARTH GROUND
CO MM O N
BA TTE RY NE GATIVE ONLY
B AT TER Y P OSITI V E ON LY
RELAY A
RELAY B
RELAY C
+ AUX P OWE R
CLASS 2 TRA NSFOR ME R
16.5 VAC 40 VA 60 Hz
Model D1640
Internally Fused - Do not short
Requir e s U n s w i t ch e d Ou t let
Do not share w ith other equipment
S4 GROUND FAULT D ETECT
Enabled
Disabled
RED
ON wh en co m mu n i ca t i ng
OF F whe n idle
PHONE LINE SEIZED LED
TIP
RING
TELCO CORD MODEL D1 61
PROGRAMMABLE
ALARM OUTPUTS
Termin als
SW ITCH ED A UX
and6 7
Ter minal 8
Point 3 Point 4
161514
P oint 1 Point 2
1211 13
CA UT I O N:
Avoid damage to Panel.
Do not connect 24 V to terminals.
Maxim um char ging current 1.4 A
1 - (Optional): For 24 V applications use a UL Listed
24 VDC power supply with a D130 Relay Module.
Refer to the D130 Installation Instructions
(P/N: F01U072455) for correct wiring
requirements.
2 - D130 Relay Module
3 - D125B Powered Loop Interface Module
4 - To UL Listed 2-wire smoke detectors. Refer to
Two-Wire Smoke Detectors in the D9412GV3/
D7412GV3 Approved Applications Compliance
Guide (P/N: F01U143069) for a listing of
compatible two-wire smoke detectors.
5 - P105F 1 kΩ EOL resistor (P/N: 14-03130-004):
Suitable for non-powered initiating and
supervisory devices such as pull stations, heat
sensors, and valve tampers.
6 - P105BL1 1kΩ EOL resistor (P/N: 16179B): For
typical burglar alarm applications.
7 - D129 Dual Class A Initiation Circuit Module:
Provides optional Waterflow Alarm Retard
feature. Not suitable for two-wire smoke
detectors.
All external connections except Terminal 5 (battery positive) are power limited.