D9412GV3/D7412GV3 | Operation and Installation Guide | 4.0 Installation
.
Bosch Security Systems, Inc. | 2/10 | F01U143070-01 15
3.3.12 Event Log
The system stores from 500 to 1000 events and event
modifiers from all areas in its event log. Event
modifiers add information about an event to the log.
Some events are always followed by a modifier. For
example, the system adds at least two items to the
log each time an area is armed or disarmed, the Open
(or Close) event and an event modifier showing the
previous arming state.
All events and their modifiers can be stored even if
the control panel does not send a report for them. The
log can be viewed at a keypad, printed locally using
the D9131A Parallel Printer Interface Module and a
parallel printer, or uploaded using Remote
Programming Software (RPS).
For a list of the log events and event modifiers, refer
to the appendix in the user’s guide for the keypad.
3.3.13 Ground Fault Detection
The Earth Ground Terminal on the control panels is
electrically isolated from all other terminals to allow
the D9412GV3 and the D7412GV3 to detect ground
fault conditions. A Ground Fault Detect Enable switch
(S4) is located just under Terminal 10, Earth Ground,
on the control panel. Refer to Section 4.5.2 Ground
Fault Detect Enable on page 17 for information on
operating this function.
3.3.14 Ground Fault Detection Added Feature
When Ground Fault Detect is enabled (S4 closed),
Points 1 to 8 can be used for non-powered fire-
initiating devices such as heat detectors, four-wire
smoke detectors, and pull stations. A D125B Powered
Loop Interface or a D129 Dual Class A Interface
Module is not required when connecting the non-
powered fire-initiating devices to Points 1 to 8.
3.3.15 Conettix Functions
The D6600 Conettix System supports data network
communications. Conettix allows the D6600 receiver
to connect to network topologies, specifically
Ethernet. Conettix also allows this receiver to process
messages to and from most networks using TCP/IP
protocols. Connecting to a data network is possible
using the COM4 or COM1 connection from the D6600
receiver to the D6680 Network Adapter. Alarm control
panels can send reports through telephone lines or
Ethernet and token-ring data networks to the D6600
receiver and then to the central station automation
software or the network printer through a local area
network (LAN) or wide area network (WAN). The
network can monitor the status of alarm control
panels.
3.3.16 Programming
Use the Bosch Security Systems D5200 Programmer
or the Remote Programming Software (RPS) to
program the D9412GV3 and D7412GV3 Control
Panels. Refer to the D9412GV3/D7412GV3 Program
Entry Guide (P/N: F01U143071) for programming
options.
3.3.17 Other Features
D9412GV3 and D7412GV3 Control Panels have
many programmable features. Some of the features
are listed below. Complete details on all features are
in the D9412GV3/D7412GV3 Program Entry Guide
(P/N: F01U143071).
Supervision of AC (primary power), battery
(secondary power), Zonex and SDI buses, central
processing unit (CPU), up to three printers, and
two telephone lines
Automatic System Test Reports
Remote access for programming, diagnostics,
and log uploads using the remote programming
software (RPS)
Fire alarm verification
Programmable alarm output
Programmable relay output using the D8129
OctoRelay Module
Opening and closing windows
Skeds (scheduled events)
4.0 Installation
4.1 Installation Preparation
This section contains a general installation procedure
and refers to other sections of the document for
detailed instructions.
Review this document and the D9412GV3/D7412GV3
Program Entry Guide (P/N: F01U143071) before
beginning the installation to determine the hardware
and wiring requirements for the features used.
Have the following documentation available when
reading through this guide:
D9412GV3/D7412GV3 Program Record Sheet
(P/N: F01U143072)
Security System Owner’s Manual
(P/N: 71-06633-000) and GV3 Series Owner’s
Manual Supplement (P/N: F01U143082)
Installation manual for keypad or annunciator
(D1255 all models, D1255RB, D1256, D1256RB,
D1257, D1257RB, D1260 all models, or D720 all
models)
Before installation, become familiar with the operation
of the D5200 Programmer or the RPS.
Vue de la page 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 75 76

Commentaires sur ces manuels

Pas de commentaire