D9412GV3/D7412GV3 | Operation and Installation Guide | 13.0 Programmer and Accessory Connections
64 Bosch Security Systems, Inc. | 2/10 | F01U143070-01
If supervised and the module does not respond to
control panel supervision polls, SERVC SDI 88
appears at the keypad. The report to the receiver
includes the address of the troubled module indicating
which module needs service.
13.0 Programmer and
Accessory Connections
13.1 Programmer Connector
Refer to the D5200 Operation Manual
(P/N: 74-06176-000) for complete information on
using the D5200 programmer.
To connect and disconnect the programmer:
1. Lock the Reset Pin (Figure 30).
2. Connect the D5200 Data/Power cord to the
programming connector on the control panel
(Figure 31).
3. Perform the desired programming function (send
or receive program).
4. Disconnect the programmer.
Figure 30: Reset Pin
Reset Pin
Disable all except Battery
Charg ing and Programming
PERIPHER AL DEVICE CONNECTIO NS
RED PO WER +
YELLOW
D ATA BUS A
GR EEN D AT A BUS B
BLACK C OM MO N
1
2
1 - Reset Pin locked (closed)
2 - Reset Pin normal (open) for normal control
panel operation
13.2 Programmer Access Reports
When a program is sent to the control panel, the
control panel sends a Prog Access OK report 10 sec
after the handler exits or when the programmer
disconnects. The prompt in routing must be
programmed Yes to send this report.
13.3 Accessory Connector
Use the accessory connector to connect the control
panel to the D928 Dual Phone Line Switcher. The
accessory connector is on the bottom right corner of
the I/O board (Figure 31). The D928 lets the control
panel use two telephone lines to send reports.
Refer to Section 7.11 D928 Dual Phone Line Switcher
on page 32 for installation and operating instructions.
Figure 31: Programmer and Accessory
Connections
1
2
21 22
Reset Pin
Disable all except Battery
Charging and Programming
PERIPHERAL DEVICE CON NECTIONS
RED POWER +
YELLO W DATA BUS A
GREEN DATA BUS B
BLACK COMMON
ZO NE X OU T 1
ZONEX IN 1
N.F.P.A.
Style 4.0
Signaling
Line
Circuits
26
ZO NEX POWER +
24
ZO NEX COMMO N
23
ZO NEX OUT 2
ZO NEX IN 2
Operat io n M onit or LE D
Pu lse s whe n No rmal
Flick er s wh en Rin ging
GREEN
D5 200/D5 360
PROG CONN
Poi nt 8, S3 Option
Clos ed = 1 k
Ω
EOL
N or m al Ope r ati on
Op en =AB-1 2 UL
Bel l Box 2 20 k
Ω
2525
1 - Accessory connector
2 - Programming connector