Bosch DiBos Micro Guide d'installation Page 77

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 158
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 76
DiBos/DiBos Micro Default Configuration | en 77
Bosch Sicherheitssysteme GmbH Installation Guide F.01U.033.308 | V7 | 2009.09
6.5.5 Configuring Automatic Teller Machines
Inputs and outputs menu > Automatic teller machine tab
A maximum of 4 automatic teller machines, each with 2 inputs, can be connected to one video
system.
1 Automatic teller machine Click the tab.
2 Interface: Select the interface.
3 Status query [h]: After this time interval, the system checks repeatedly
whether the connected automatic teller machines
have completed a transaction. Enter the time in
hours. Example: Entering 2 would mean that a check
is run every 2 hours. Entering 0 would mean that no
check is run.
Note:
If the system does not display a transaction, an error
message is sent. If the connection between DiBos and
the automatic teller machine is faulty, another error
message is sent.
4 Type Click the down arrow in the column and select
whether an input is to be configured or not.
The input is assessed.
The input is not assessed.