148 en | Connections DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09 Installation Guide Bosch Sicherheitssysteme GmbH
9.11.6 Connecting to NZ 1060
V.24 connection to NZ 1060
Ideally, interfaces 6 to 9 should be used; connection to interfaces 2 to 5 is also possible on a
project-specific basis.
Program the appropriate interface to AUX (1200 baud), insert bridges at SIE (V1, V3) for V.24
interface.
20 mA connection to NZ 1060
Ideally, interfaces 6 to 9 should be used; connection to interfaces 2 to 5 is also possible on a
project-specific basis. Program the appropriate interface to AUX (1200 baud), insert bridges
at SIE (V2, V4) for 20 mA interface.
1 Video system 5 ZAN
2COM x 6SIE
3 Max. 25 m 7 ZVE (SW issues: 18033.0 A6.2, 18033.2
A6.2, 18033.3 A6.2)
4 NZ 1060
1 Video system 5 NZ 1060
2COM x 6GOM
3OVS 7ZAN
4 Range max. 1000 m