Camera Browser Interface Network | en 85
Bosch Security Systems Software manual AM18-Q0611 | v5.50 | 2012.03
2. Enter the Password that the Radius server expects from
the camera.
14.2.5 RTSP port
If necessary, select a different port for the exchange of the
RTSP data from the list. The standard RTSP port is 554. Select
Off to deactivate the RTSP function.
14.2.6 UPnP
Select On to activate UPnP communication. Select Off to
deactivate it.
When UPnP is activated the camera reacts to requests from the
network and is registered automatically as a new network
device on the inquiring computers.
Note:
To use the UPnP function on a computer with Windows XP or
Windows Vista, the Universal Plug and Play Device Host and the
SSDP Discovery services must be activated
This function should not be used in large installations due to
the large number of registration notifications.
14.2.7 TCP metadata input
The device can receive data from an external TCP sender, for
example an ATM or POS device, and store it as metadata.
Select the port for TCP communication. Select Off to
deactivate the function. Enter a valid Sender IP address.
14.2.8 Quality of Service
The priority of the different data channels can be set by
defining the DiffServ Code Point (DSCP). Enter a number
between 0 and 252 as a multiple of four. For alarm video you
can set a higher priority than for regular video and you can
define a Post Alarm Time over which this priority is maintained.