Fig. 5.14 Location of the RS-232 serial interface
The AMC is created like a PC, so you cannot build a 1:1 connec-
tion, but cross the data wires using a null modem cable for
example.
5.8 Ethernet Interface
The AMC2 4W offers an additional 10/100 Mbit/s Ethernet auto-
sensing interface to connect to a local area network or host
computer.
i
NOTE!
A complete connection diagram of the RS-232 host interface is
shown in Figure 7.3.
!
CAUTION!
Use either a CAT5 crossover cable to connect the AMC2 4W
directly to a computer’s network interface or a standard CAT5
patch cable to connect the AMC2 4W to a network hub or net-
work switch.