Bosch GLL 3-80 P Professional Manuel d'utilisateur Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 196
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
12 | English
1 619 929 L95 | (29.11.12) Bosch Power Tools
Do not use the laser viewing glasses as sun glasses or in
traffic. The laser viewing glasses do not afford complete
UV protection and reduce colour perception.
Have the measuring tool repaired only through quali-
fied specialists using original spare parts. This ensures
that the safety of the measuring tool is maintained.
Do not allow children to use the laser measuring tool
without supervision. They could unintentionally blind
other persons or themselves.
Do not operate the measuring tool in explosive environ-
ments, such as in the presence of flammable liquids,
gases or dusts. Sparks can be created in the measuring
tool which may ignite the dust or fumes.
Laser target plate
Keep the laser target plate 15 away from
cardiac pacemakers. The magnets on the
laser target plate generate a field that can
impair the function of cardiac pacemakers.
Keep the laser target plate 15 away from magnetic data
medium and magnetically-sensitive equipment. The
effect of the magnets on the laser target plate can lead to
irreversible data loss.
Product Description and
Specifications
Please unfold the fold-out page with the representation of the
measuring tool and leave it unfolded while reading the operat-
ing instructions.
Intended Use
The measuring tool is intended for determining and checking
horizontal and vertical lines.
Noise Information
The A-weighted sound pressure level of the audio signal at
one meter distance is 80 dB(A).
Do not hold the measuring tool close to your ear!
Product Features
The numbering of the product features shown refers to the
illustration of the measuring tool on the graphic page.
1 Exit opening for laser beam
2 Battery low indicator
3 Pulse-function button
4 Pulse-function indicator
5 Operating mode button
6 Working without automatic levelling indicator
7 On/Off switch
8 Tripod mount 5/8"
9 Tripod mount 1/4"
10 Battery lid
11 Latch of battery lid
12 Laser warning label
13 Serial number
14 Magnets
15 Laser target plate
16 Measuring plate with stand*
17 Laser receiver*
18 Protective pouch*
19 Universal holder*
20 Telescopic rod*
21 Laser viewing glasses*
22 Tripod*
* The accessories illustrated or described are not included as
standard delivery.
Technical Data
Line laser GLL 3-80 P
Article number
3 601 K63 300
Working range
1)
Standard
–With pulse function
With laser receiver
20 m
15 m
5–80m
Levelling Accuracy
±0.2mm/m
Self-levelling range, typically
±4°
Levelling duration, typically
<4s
Operating temperature
10 °C ... +40 °C
Storage temperature
–20 °C ... +70 °C
Relative air humidity, max.
90 %
Laser class
2
Laser type
640 nm, <1 mW
C
6
1
Shortest pulse duration
1/1600 s
Tripod mount
1/4", 5/8"
Batteries
4x1.5VLR06 (AA)
Operating duration
–With 3 laser planes
–With 2 laser planes
–With 1 laser plane
5h
9h
18 h
Weight according to
EPTA-Procedure 01/2003
0.75 kg
Dimensions
(length x width x height)
159 x 75 x 141 mm
Degree of protection
IP 54 (dust and splash
water protected)
1) The working range can be decreased by unfavourable environmental
conditions (e.g. direct sun irradiation).
The measuring tool can be clearly identified with the serial number 13
on the type plate.
OBJ_BUCH-1046-002.book Page 12 Thursday, November 29, 2012 12:07 PM
Vue de la page 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 195 196

Commentaires sur ces manuels

Pas de commentaire