There are various functions that allow you to test that your system is operating correctly.
Horn Speaker Test
1. Press and hold button 1 until two beeps are heard.
The horn speaker will sound for two seconds.
Bell Test
1. Press and hold button 2 until two beeps are heard.
The bell output will operate for two seconds.
Strobe Test
1. Press and hold button 3 until three beeps are heard.
The strobe will now flash.
2. Press and hold button 3 until two beeps are heard.
The strobe will now stop flashing.
Walk Test Mode
Walk test mode allows you to test detection devices to ensure that they are operating
correctly. Every time you test a zone, the codepad will sound one long beep and the horn
speaker will sound one short beep to indicate that the zone has been activated when testing.
1. Enter your Master Code followed by 4 and the # button (eg. 2580 + 4 + #).
Three beeps will be heard and the STAY and AWAY indicators will begin to flash.
The codepad will beep once every second while the system is in walk test mode.
2. Activate (ie. fault and restore) all zones required to be tested.
3. When you have finished testing all zones required, press the # button to exit this
mode. Two beeps will be heard and the STAY and AWAY indicators will extinguish.
The system has now returned to the disarmed state.
Test Report
This feature is only applicable if your system is reporting via the telephone. Press and hold
button 9 until two beeps are heard. The system will send a test report.
Event Memory
This function allows you to replay back the last forty events that occurred to the system. The
event memory history will replay all alarms and arming/disarming of the system in AWAY
Mode, STAY Mode 1 and STAY Mode 2. However, the system cannot differentiate
between arming the system in STAY Mode 1 or STAY Mode 2.
How To Enter Event Memory
1. Enter your Master Code followed by 3 and the # button (eg. 2580 + 3 + #).
Three beeps will be heard. The last forty events will display one at a time via the
codepad indicators starting from the most recent event. A beep will be heard as each
event is displayed.