Arming In STAY Mode 2
STAY Mode 2 is only used when the perimeter and unused areas of the premises need to be
armed to detect any would be intruder from entering the premises and at the same time,
allowing you to move freely within an area that has been automatically isolated. Any Master
Code holder can program programming zones to be automatically isolated in STAY Mode 2.
Entry Guard Timer For STAY Mode
When arming the system in STAY Mode 2, an optional entry timer called Entry Guard
Timer For STAY Mode may be used to delay the sirens if a zone that has not been
automatically isolated has triggered into alarm condition. Entry Guard Timer For STAY
Mode is the delay time used for all zones except 24-hour zones when the system is armed in
STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer For STAY Mode has been programmed and a zone that has not
been automatically isolated has triggered, the codepad will beep twice a second until the
Entry Guard Timer For STAY Mode has expired or the system has been disarmed. If the
alarm condition has not been reset by entering your user code followed by the # button (eg.
2580#) before the Entry Guard Time For STAY Mode expires, the sirens will activate into
alarm. Only your installer can program this option.
How To Arm The System In STAY Mode 2
1. Press and hold the 0 button until two beeps are heard.
The STAY indicator will display and exit time will now commence counting.
Any zones that have been programmed to be automatically isolated in STAY Mode 2
will flash until exit time expires. At the end of exit time, all zones selected to be
automatically isolated will extinguish and the codepad will give one short beep.
Programming STAY Mode 2 Zones
Programming zones to be automatically isolated in STAY Mode 2 can only be carried out if
you have a Master Code.
How To Program STAY Mode 2 Zones
1. Enter your Master Code followed by 8 and the # button (eg. 2580 + 8 + #).
Three beeps will be heard and the STAY indicator will begin to flash.
2. Enter the zone number that you wish to have automatically isolated followed by the *
button (eg. 1* = Zone 1 / 2* = Zone 2 etc).
You will notice that the zone you have selected to be automatically isolated in STAY
Mode 2 will now flash. If you have made a mistake, enter the same zone number
followed by the # button to clear the incorrect zone.
To select additional zones to be automatically isolated in STAY Mode 2, repeat Step 2
as many times as required.
3. Press the # button when you have selected all zones to be automatically isolated in
STAY Mode 2 to exit this mode. Two beeps will be heard and the STAY and AWAY
indicators will extinguish.
12