American Dynamics Fixed Camera (Illustra 400 series)
20-1
American Dynamics Fixed Camera (Illustra 400
series)
Supported Firmware
v2.20 or later
Supported Key Functions
Video Streaming – Single, Dual
Video codec – H.264 and MJPEG
Audio Streaming – G.711 ulaw and G.726, single stream only
Dry Contact Events – is polled for dry contact event at 100ms interval
Query Device
Device Reboot
Required Network Ports
Port 80 is for HTTP
Port 554 is for RTSP
Default Username & Password
Username:admin
Password:9999
Limitations
The camera will reboot when changing codec (audio or video), resolution, frame rate, key frame
interval, video quality, audio volume, enable audio / audioin and any other audio / video
properties. The reboots will take about 20 to 30 seconds.
All audio and video streams will be lost when the camera reboots. All audio and video streams
will then need to be re-established.
When the camera is rebooting, video and audio properties may not be available to get / set new
value.
Due to camera internal resource contention, both profiles (streams) must have the same
resolution. If profiles (streams) are set to obtain different resolutions the requested FPS will not
be obtainable for MJPEG.