Bosch SE2005 Guide d'installation Page 25

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 54
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 24
Security Escort | Installation and Setup Guide | 3.0
Installation Instructions
EN | 25
Bosch Security Systems | 1/09 | 33831E
3.0 Installation
Instructions
3.1 Overview of Installation
Process
This section includes information
about the installation and setup of
the individual components and system
wiring. It is recommended that the
installation instructions that
accompany each specific component be
consulted prior to beginning any phase
of the installation.
A typical installation proceeds in the
following order:
1. The Site Survey is completed,
indicating the proposed location of
each component.
2. Wiring runs to all of the proposed
component locations and the central
console.
3. Empty enclosures are installed as
specified in the Site Survey.
4. The components are secured inside
the enclosures and connected to the
previously run wiring.
The individual components are set up
and their addresses recorded.
Note:
Use the Transponder Information
Sheet, located in the Appendix of
this document, to keep track of
receiver and alert unit addresses
and location for programming the
Transponder Database.
5. The recorded addresses are entered
into the central console and the
system is brought on-line.
6. The system is tested and tuned up
as needed.
3.2 Run System Wiring
3.2.1 General Guidelines
After the site survey and special pre-
construction verifications are
completed, the wiring can be run
between the proposed locations of the
system components and the central
console. See specific installation
instructions accompanying each
component for wiring details.
Table 6
indicates the specifications for the
wiring.
Table 6: Wiring Guidelines
Application
From To
Diagram
Reference* Gauge
Conductor
s
Maximum
Distance Notes
Transponde
r
Transforme
r
1 1.5 mm
(16 AWG)
2 15 m
(50 ft.)
Standard lamp
cord
Alert unit 2 1.2 mm
(18 AWG)
4 900 m
(3000 ft.)
per bus
Solid, not
twisted, not
shielded
Receiver 2 1.2 mm
(18 AWG)
4 900 m
(3000 ft.)
per bus
Solid, not
twisted, not
shielded
SE485 3 0.5 mm
(24 AWG)
4 wire, 2
twisted
pair
See Table
7
IMPORTANT!
Must be
twisted pair,
not shielded.
CAT 5 cable
preferred
Siren/stro
be
4 1.2 mm
(18 AWG)
4 15 m
(50 ft.)
Solid, not
twisted, not
shielded
Alert Unit Transforme
r
5 1.5 mm
(16 AWG)
2 15 m
(50 ft.)
Standard lamp
cord
Alert Unit Siren/stro
be
6 1.5 mm
(18 AWG)
4 15 m
(50 ft.)
Solid, not
twisted, not
shielded
* See the corresponding numbers in Figure 5, Figure 6, and Figure 7.
Vue de la page 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 53 54

Commentaires sur ces manuels

Pas de commentaire