DS7400XiV4-EXP | User Guide | 10.0 Testing Your System EN | 27
Bosch Security Systems | 6/05 | 4998154961B
10.0 Testing Your System
10.1 Zone Test
The zone test confirms that detectors report alarms to the keypad. A zone test works on all zones, except 24-hour
zones and fire zones. While the keypad is in a zone test, no control panel alarms activate an alarm, except 24-hour
zone alarms and fire alarms; these alarms override the zone test function.
This test requires you to manually alarm each zone.
At the start of the test, if programmed, a report is sent to the central station followed by reports on the individual
zones as they are tested. When the zone test is complete, a test restoral report is sent to the central station.
If you perform this test from a Master Keypad, the keypad must be in Single Partition Mode. Zone tests are not
available from RF (wireless) keypads.
Test the system weekly.
Table 25: Zone Test
Type of Test Command Sequence What Happens What To Do
Zone Test [PIN][#][8][1] “Test Zone” is displayed followed by the
numbers of the zones that were not tested. *
The zone LEDs of any untested zones flash. **
“Now Testing” is displayed followed by the
number of the zone currently being tested. *
The LED for the zone currently being tested
turns on steady. **
As each zone is tested, “Test Zone” appears
followed by the remaining untested zones. *
As each zone is tested, its LED turns off. **
Test each zone as
instructed by your
installing company.
Exit the Zone Test using
[PIN][#].
* Text Keypad only
** LED Keypad only