D9412GV2/D7412GV2 | Program Entry Guide | 2.0 GV2MAIN EN | 50
Bosch Security Systems, Inc. | 10/08 | F01U003636-04
A# Entry Warning
Default: Yes
Selection:
Yes or No
Yes Pulse the alarm output for the last 10
sec of the Entry Delay time.
No Do not pulse the Alarm Bell output
during the Entry Delay time.
When enabled, the Alarm Bell output pulses on and
off every 2 sec for the remaining 10 sec of the Entry
Delay time.
For SIA CP-01 Compliance
A# Entry Warning must be set to Yes.