D7212GV2 | Operation and Installation Guide | 3.0 Overview
10 Bosch Security Systems, Inc. | 2/07 | F01U003805-02
Table 3: Compatible Accessories (continued)
Model Title Fire Intrusion
D1255W Text Keypad (white) X X
D1256 Fire Keypad (Command Center) X
D1257 Fire Alarm Annunciator X
D1260/D1260B
1
Keypads X X
D1640 16.5 VAC 40 VA Transformer X X
D8004 Transformer Enclosure X X
D8125 POPEX Module X X
D8125MUX Multiplex Bus Interface X X
D8125INV
2
Wireless Interface Module X
2
D8128D OctoPOPIT Module X X
D8129 OctoRelay Module X X
D8130 Release Module X X
D8132 Battery Charger Module X X
D9127U/T POPIT Module X X
D9131A Parallel Printer Interface Module X X
ZX776Z PIR Motion Sensor [15 m (50 ft)] with POPIT X
ZX794Z PIR Motion Sensor [24 m (80 ft)] with POPIT X
ZX865
PIR/Microwave Motion Sensor [+1.7°C (+35°F)] with POPIT
X
ZX938Z PIR Motion Sensor [18 m (60 ft)] with POPIT X
ZX970
PIR/Microwave Motion Sensor [+1.7°C (+35°F)] with POPIT
1
Version 1.03 or above
2
The D8125INV was not investigated by UL. Do not use D8125INV in UL Listed installations.
3.3 Features in the D7212GV2
3.3.1 SDI Molex
®
Connector
Use the SDI Molex Connector to connect easily an
SDI device with the SDI bus, without needing to
disconnect wires connected to the SDI terminals.
Possible applications include:
Connecting a DX4010i to program the control
panel with Remote Programming Software (RPS)
at the premises
Connecting a keypad to test the control panel.
Do not connect the D5200 Programmer to
the SDI Molex connector.
3.3.2 Tip and Ring Posts
The tip and ring posts allow connecting a phone or
buttset for the purpose of troubleshooting
communications between the control panel and the
central station. This connection allows monitoring of
the dial tone, handshaking tones from the receiver, and
communications signals.
3.3.3 Super Capacitor
The D7212GV2 Control Panel has a capacitor called
Super Cap. This component preserves the parameters
stored in the control panel’s RAM chip when the
lithium battery is replaced. The Super Cap can retain
voltage for up to 30 minutes after the lithium battery is
removed.
Plan to replace the lithium battery after 3 to 5 years of
continual service.
When replacing the lithium battery, ensure
that you disconnect the primary AC power
and secondary battery power from the
control panel before you remove the old
battery. Then install the new battery and
connect the primary AC and secondary
battery power to the control panel.
3.3.4 Telephone Line Sniff
The D7212GV2 Control Panel monitors the phone line
for the programmed supervision interval before
indicating a phone line trouble. If trouble occurs, refer
to Central Station Communications Symptoms in the
D9412GV2/D7412GV2 Troubleshooting Guide
(P/N: F01U011024).