3.0 Installation
3.1 Mounting
The D1260 Command Center is a low profile, surface-mounted unit. It can also be mounted using the following optional
packages:
• D56 Command Center Keypad Conduit Box - Protected surface mount or flush mount
• D55 Command Center Desk Stand – Desktop
• D54B-1260 Command Center Flush Mount Kit (Brass)
• D54C-1260 Command Center Flush Mount Kit (Stainless)
3.1.1 Location Recommendations
• Do not mount the command center in a location where it will be exposed to direct sunlight. Direct sunlight
can interfere with the D1260 display screen visibility and damage internal components.
• Do not mount the D1260 in wet or moist locations.
3.1.2 Mounting the Backplate
The backplate for the D1260 keypad has a variety of
mounting holes to accommodate different mounting
standards.
1. Standard 3-point mounting
2. Single-gang electrical box
3. Dual-gang electrical box
4. Triple-gang electrical box
Figure 6: D1260 Backplate Mounting Options
To correctly mount the backplate, follow the steps below:
1. Remove the backplate from the D1260 by using a flat-blade
screwdriver to press the two small tabs on the bottom of the D1260.
2. Lift away the D1260 from the backplate.
3. Ensure that the backplate is right-side up.
4. Line up the mounting holes with the desired mounting method
(Standard 3-point, Single, Dual, or Triple-gang electrical boxes).
5. Feed the 4-wire flying lead (from the panel) through one of the square holes at the bottom of the
mounting plate.
6. Insert and tighten screws through the appropriate mounting holes to secure the mounting plate to the
wall.