16.1 Redirecting Outputs to the
Codepad Buzzer
Multiple output event types can be directed to the
codepad buzzer so that the buzzer can indicate a
number of events.
To redirect an output to the codepad buzzer, select
an output and program it for the desired Output
Event Type. If the output is functioning correctly,
add 8 to the first (tens) digit of the Output Event
Type.
Example
3,0 Communications Failure
This event operates after the dialer makes all possible
attempts to reach the base station receiver. It is reset
when the panel receives the first Kiss-off. This
Output Event Type is not applicable to domestic
reporting.
To redirect this Output Event Type to operate a
codepad buzzer, program the Output Event Type as:
11,0 Communications Failure
The codepad buzzer operates instead of the output
that was programmed. Output 3 is no longer
functional and cannot be used for any other Output
Event Type.
16.2 Output Event Types
There are approximately 75 Output Event Types.
Two numbers designate each Output Event Type.
Program these numbers into the appropriate
locations for the output.
All reset times reference Polarity 1 and 8.
Reset times vary depending on the
selected polarity.
0,0 EDMSAT - Satellite Siren (Output 1 Only)
This output controls all functions of the SS914
Satellite Siren (EDMSAT). The Speaker Indication
Beeps option does not function through the satellite
siren for remote operations. No polarity is required
for this Output Event Type.
0,1 System Armed
This output operates when the system is armed. The
output is reset when the system is disarmed. If the
system is partitioned, this output operates when both
areas are armed in AWAY Mode or STAY Mode 1.
0,2 System Disarmed
This output operates when the system is disarmed.
The output is reset when the system is armed. If the
system is partitioned, this output operates when both
areas are disarmed.
0,3 Armed in STAY Mode
This output operates when the system is armed in
STAY Mode 1 or STAY Mode 2. The output is reset
when the system is disarmed. If the system is
partitioned, this output operates when either area is
armed in STAY Mode 1.
0,4 Armed in AWAY Mode
This output operates when the system is armed in
AWAY Mode. The output is reset when the system is
disarmed. If the system is partitioned, this output
operates when either area is armed in AWAY Mode.
0,5 Auto Arm Pre-Arming Alert Time
This output operates during the time period before
the control panel is automatically armed in AWAY
Mode or STAY Mode 1. The output is reset when
the control panel is automatically armed in AWAY
Mode or STAY Mode 1. The Auto Arming Pre-Alert
Time is programmed in Location 481 (refer to Section
17.11 for more information).
0,6 Exit Warning with All Zones Sealed or
Entry Warning
This output operates during Exit Time when the
control panel is armed and all zones are sealed. The
output is reset when Exit Time expires.
This output operates again during Entry Time and is
reset when Entry Time expires or the system is
disarmed.
This output also operates if a zone is activated when
the system is armed in STAY Mode 1 or STAY
Mode 2 and the Entry Guard Timer for STAY Mode
is programmed in Locations 472 and 473 (refer to
Section 17.5 on page 78).
0,7 Exit Warning
This output operates during Exit Time when the
system is armed. The output is reset when Exit Time
expires.
0,8 Exit Warning Finished
This output operates after Exit Time expires when
the system is armed. The output is reset when the
system is disarmed.
0,9 Kiss-Off after Exit Time
This output operates after the first successful
transmission to the base station receiver when Exit
Time expires. The output is reset when the system is
disarmed.
0,11 Entry Warning
This output operates when during Entry Timer 1,
Entry Timer 2, or Entry Guard Timer for STAY
Mode. The output is reset when the Entry Time
expires.