ICP-CC488 | Installation Guide | 8.0 Alarm Link Software EN | 41
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Program the Call Back Telephone Number in
Locations 159 to 174 (refer to Section 11.9 on
page 51).
Disable Option 1 in Location 180 (refer to Section
8.2 Alarm Link Options on page 41).
The control panel is set so the client controls when a
remote connection is established.
To dial the remote computer:
Press and hold [6] until two beeps sound on the
remote codepad.
8.1.2 Remote Connection without Callback
Verification
Remote connect without callback verification is
useful if you must perform Upload/Download
functions from multiple locations.
There are two methods to disable callback
verification. Using this feature reduces the security of
the control panel.
Method One
Method one allows you to call the control panel from
any remote location without the control panel calling
back to the computer to establish a link. When using
this method, the customer cannot initiate a modem
call by holding down [6].
To program method one:
1. Program Locations 159 to 174 for the Call Back
Telephone Number to 0 (refer to Section 11.9 on
page 51).
2. Select Option 1 and disable Option 2 in Location
180 (refer to Section 8.2 Alarm Link Options on
page 41).
The control panel allows a connection of the first call
without calling the remote computer back.
Method Two
Method two allows you to program a callback
telephone number so that the customer can still
initiate a modem call when required. When you call
the control panel from a remote location using the
computer, the control panel does not call back the
remote computer to establish a link.
To program method two:
1. Program the Call Back Telephone Number in
Locations 159 to 174 (refer to Section 11.9 on
page 51).
2. Select Option 1 and disable Option 2 in Location
180 (refer to Section 8.2 Alarm Link Options on
page 41).
The control panel allows a connection of the first call
without calling back the remote computer to make
contact. It allows the customer to initiate a modem
call by holding down [6].
8.1.3 Remote Connection with Callback
Verification
Remote connect with callback verification offers the
highest degree of data security by incorporating a
two-level security check.
The first level is provided because the Installer Code
and the Subscriber ID Number must match those of
the control panel. The sec level of security exists
because the control panel calls the programmed
callback telephone number to establish the valid
connection.
To program the control panel for remote
connection with callback verification:
1. Program the Call Back Telephone Number in
Locations 159 to 174 (refer to Section 11.9 on
page 51).
2. Select Options 1 and 2 in Location 180 (refer to
Section 8.2 Alarm Link Options on page 41).
8.1.4 Direct Connection
The direct connect feature gives the installer a simple
method to program the ICP-CC488 Control Panel
using a portable computer. Because telephone lines
and modems are not required, programming of the
control panel is easily completed in min.
To use the direct connect feature, connect the CC808
Direct Link Cable between the correct serial port on
your IBM or compatible computer and the auxiliary
module socket on the control panel.
To use the direct connect feature, it is not necessary
to select Option 1 Location 180. The direct connect
feature ignores this option.
8.2 Alarm Link Options
Location
180
1 Enable upload/download using Alarm Link
2 Enable Alarm Link call back
4 Terminate Alarm Link connection on alarm
8 Reserved
When programming these locations, you can select
any of four options. You can select any combination
of the options by programming a single value.
Calculate this value by adding the option bit
numbers together. Refer to Section 7.3 Programming
Option Bits on page 36 for more information.
1 – Enable Upload/Download Using Alarm Link
Select this option to use the CC816 Alarm Link
Software to program the control panel remotely. The
control panel does not respond to the Alarm Link
Software if this option is not selected. Refer to Section
8.0 Alarm Link Software on page 40 for more
information.