Bosch Water Wizard 600 Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Enregistreurs vidéo numériques (DVR) Bosch Water Wizard 600. Bosch Water Wizard 600 Operating instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 7
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
BISN0047.0 26/06/2007 Page 1
Installation / Operating Instructions
GOOD.BEETER>BOSCH
Water Wizard 600
Continuous Flow Gas Water Heater
1 Main Cover 5 Cold Water Inlet
2 Inspection Window 6 Hot Water Supply
3 Access Panel 7 Mounting Point
4 Gas Inlet 8 Horizontal Flue
Fig. 1
This appliance must be installed in accordance with the manufacturer’s installation instructions
,
AG 601, NZ 5261, AS3500.4.2
and all Local Water,Building and Gas fitting regulations
To be installed and serviced only by an authorised person
This appliance is not suitable for use as a pool heater
The “authorised installing person” is responsible for :
1. Correct commissioning of this appliance.
2. Ensure unit performs to the specifications stated on the rating label.
3.. Demonstrate operation of unit to customer before leaving.
4. Hand these instructions to customer.
Failure to install this appliance in accordance with these installation instructions may
void warranty
In the interest of continued product improvement, Bosch reserves the right to alter
these specifications without notice
Troubleshoot resources for homeowner
http://waterheatertimer.org/Troubleshoot-Bosch-Tankless-water-heater.html
Vue de la page 0
1 2 3 4 5 6 7

Résumé du contenu

Page 1 - Water Wizard 600

BISN0047.0 26/06/2007 Page 1 Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas W

Page 2 - Water Temperature Adjustment

BISN0047.0 26/06/2007 Page 2 Installation Install only on an external wall, as close as possible to the most frequently used hot

Page 3 - Conversion and Spare Parts

BISN0047.0 26/06/2007 Page 3 Characteristic Data Pilot orifice diameter (mm) NG 0.30 LPG 0.19 TG 0.56

Page 4

BISN0047.0 26/06/2007 Page 4 Operating instructions Open all hot water taps to expel any air prior to lighting Remove front cover b

Page 5 - Maintenance

BISN0047.0 26/06/2007 Page 5 Commissioning Natural Gas Inlet Pressure Adjustment With the gas supply turned off, remove sealing scr

Page 6 - Fault Finding

BISN0047.0 26/06/2007 Page 6 Fault Finding. Problem Possible Cause Solution Appliance does not light No gas supply Blocked pilot

Page 7 - Warranty Details

BISN0047.0 26/06/2007 Page 7 Warranty Details Your Bosch Hot Water Unit is guaranteed as follows: For appliances used in domestic

Commentaires sur ces manuels

Pas de commentaire