Functions
Advanced False Alarm Reduction
The Easy Series system guards against user-generated
false alarms through design features such as
Graduated Annunciation and Intelligent Threat
Assessment. Easy Series uses enhanced false alarm
verification methods that exceed industry false alarm
reduction standards.
Graduated Annunciation
The system gradually increases the control center
volume, changes the animation of the control center
display, and incrementally pulses the warning devices.
The control center notifies users when the system is
preparing to send an alarm and provides options to
cancel reports, reducing false alarms.
Alarm Verification
The following alarm verification methods reduce false
alarms without compromising usability or reliability.
Two-way Audio Verification: Provides remote
customers the ability to listen to and speak with
users at the protected premises.
Sequential Verification: When two or more input
sensors activate within a specified time period, an
intrusion alarm is considered verified. For example, if
a door sensor and a motion detector both sense
alarms, the system sends a verified alarm report.
Intelligent Threat Assessment: The Easy Series uses
protection levels, input types, input conditions, and
system event timing to assess a potential threat. If
the threat reaches a specific threshold, the system
sends a verified alarm report.
Easy Series Intrusion Control Panel Configuration
Users can configure the Easy Series with the necessary
regional parameters for a specific country without
changing hardware. Installers can configure the system
using their language of choice and then set the system
to the appropriate language for the user. Installers can
remotely program the system using a telephone or
Remote Programming Software (RPS). A voice
prompted installer mode reduces service and
installation costs while ensuring accurate
programming.
Remote Programming Software (RPS)
RPS is a separate software package that allows
computers equipped with the Microsoft Windows
operating system and a modem to act as a remote
programming, record storage, remote control, and
troubleshooting tool for specific control panels.
Certifications and approvals
Region Certification
Europe CE ICP-EZM2-EU, ICP-EZM2-LC
Technical specifications
Enclosure
Dimensions (H x W x
D):
37 cm x 31.8 cm x 8.5 cm (14.5 in x 12.5 in x
3.25 in)
Construction
Material:
Cold-rolled steel, zinc seal, 0.36 mm thick
(20 Ga.)
Environmental Considerations
Relative Humidity: 93% at 32°C 2°C (89.6°F 35.6°F)
Operating
Temperature:
-10°C to +49°C (14°F to +120°F)
CE: -10°C to +40°C (+14°F to +104°F)
NF A2P: -10°C +55°C (+14°F to +131°F)
Storage Temperature: -10°C to +55°C (+14°F to +131°F)
Protection Level IP 30 - IK 04
Supervised Points
On-board Hardwire: 8
Single or dual end-of-line (2.2 k EOL) tamper
point support
Point 1 supports two-wire smoke detectors
All points support four-wire smoke detectors
Enclosure tamper input (does not reduce
point capacity)
Reaction time lower than 250ms
Programmable Outputs (PO)
On-board: 4
PO 1 only: Configurable relay
PO 2 to PO 4: Configurable solid state
PO 4 only: Internal supervised speaker driver
option
PO 1 Relay Rating: Contacts: 2 A with no jumper installed;
resistive loads only; in a NF A2P certified
installation: 1 A
Output: 1.2 A with jumper installed; resistive
loads only; in a NF A2P certified installation 1
A
Operating Voltage: 30 VDC maximum
PO 2 to PO 4 Rating: 400 mA current sink
Number of...
Users: 22
User 1: Master user
Users 2 to 21: System users
User 22: Duress user
Events: 500 history events, stamped with time and
date
Tokens and Key Fobs: One per user (User 22 does not receive a
token or key fob)
Phone Line
Phone line trouble
voltage
Trouble condition occurs when the phone line
voltage is between 1.10 V and 4.75 V
Control Panel Power Requirements