DINION 5000 AN Connection and mounting | en 15
Bosch Security Systems Installation Manual AM18-Q0644 | v1.0 | 2013.03
4.3 Alarm and relay connector
Figure 4.4 Alarm and relay connector pins
Max. wire diameter AWG 22-28 for both stranded and
solid; cut back 5 mm (0.2 in) of insulation.
Alarm output relay switching capability: Max voltage 30VAC
or +40 VDC. Max 0.5 A continuous, 10 VA.
Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled
with 22 kOhm pull-up to +3.3 V.
Alarm in: configurable as active low or active high.
Max. 42 V allowed between camera ground and each of the
relay pins.
Pin Alarm socket
1 Alarm in
2not used
3 Relay out contact 2
4 Alarm in ground
5not used
6 Relay out contact 1
ALARM
1
2
3
4
5
6
5 mm
(0.2 in)