Power Trouble ( Yes or No ) : “ Y “ indicates that the SC8016 has detected a loss of AC power. Updates to the
Yes/No status indication of Power Trouble may not be immediately reported to the SC9000 computer. The “Power
Trouble” and “Power Restore” messages are RIDER category type of events, and may not be reported as soon as
the event occurs. The SC8016 will include both of these type messages as part of the next message packet sent by
the SC8016 to the SC9000 computer.
Low Battery ( Yes or No ) : An indication reflecting the results of the last SC8016 battery voltage test. A dynamic
battery test is preformed every time the panel is armed and then every four hours afterwards.
Ch. Busy ( Yes or No ) : If Report CHANNEL BUSY/CLEAR is (y)yes, then system and remote channel busy and
channel clear reports will be send to the automation system. Otherwise, system reports will be send as RF
troubles/restores on 0000, and remote reports will not be reported.
Panel Arm : Enabled or Disabled. Current Panel arming status is displayed. This state can be toggled by the central
station by highlighting the field and hitting the space bar
Outputs,2,3,4: An indication of the Disabled or Enabled status of the (3) SC8016 Outputs. The Status each Output is
reported in plain language text; Output2: DISABLED. The text displayed, in the Output status is determined by the
Line Number selected, if any, from the Output Translation table on the Radio Communicator account Setup #2 menu
for each Output. If “- - - - - - - -” is displayed in the Output status field instead of text, the Output Type has been
programmed to a type other than “ 0 ” on the Radio Communicator account Setup menu #2. Any output type besides
“0” means the output status is controlled by the SC8016 in the field.
Notes: Four (4) lines, 35 characters each line of plain language text: The Notes are displayed as they were entered
in the Radio Communicator account Setup #1 menu. Notes usually identify customer name, address, phone number,
etc.
.
Controlling the SC8016’s Output
Safecom can remotely operate up to 3 outputs on the SC8016 as well as Arm and Disarm from the ST150 software. The
SC8016 needs to be programmed for this function to work. See the SC8016/Solution-16 Safecom Installation Manual for
further details.
To Send a Manual Output Enable Command to an SC8016 from the SC9000
1. Press the F1=SELECT option from the System Status Menu Command Window. The Select a Remote menu will be
displayed. Enter the Radio Communicator number in the “Select a remote:” field and press ENTER.
2. The operator message “Polling remote XXX depress ALT-X to fail. . .” is displayed until an acknowledge (ACK)
message is received from the SC8016; then the Remote Status screen will be displayed allowing the operator to view
the status of the SC8016.
3. Using the “
↓↑
” keys position the cursor on the desired output to enable. That output to be enabled will be highlighted
light blue to indicate a modification may be made by the operator. Then press the SPACE bar once. The operator
prompt “Transmitting to remote XXX, depress ALT-X to fail ...” is displayed until an ACK is received from the SC8016.
The SC8016 will then enable the input selected and send the “Input X ENABLED” message to the SC9000 computer.
The input is now enabled and is controlling whatever devices (air conditioners, pumps, tank valves, sirens, lights,
CCTV cameras, access control devices, and arm/disarm Alarm Panels) it is connected to. The English text displayed
(ENABLED) in the Output status is determined by the Line Number selected from the Output Translation table (XLAT)
on the Radio Communicator account Setup Menu #2 for each Auxiliary Output. Some Central Station operators prefer
to use the output translation table (XLAT) to allow the output relay to report “PUMP ON” or “DISARMED” instead of
the default “ENABLED” or “DISABLED”
NOTE: In the event of a SC8016 Restart (loss of both AC and Battery backup), all of the Output Relays will return to the
DISABLED condition. This condition will then be reported to the Central Station directly following the RESTART message.