installed for remote access to CCTV at all school
locations.
H. New systems shall be connected to each school’s
LAN using CAT 5e wiring. Provide and install
network access jacks local to the existing
Andover Control systems. Contractor is
responsible for all coordination with the Bristol
IT department.
I. Vendor will coordinate activating the new
security systems with the City of Bristol’s
existing monitoring services for fire and
security systems.
1.6 SUBMITTALS
A. Product Data: Components for sensing,
detecting, access control, systems integration,
and control, including dimensions and data on
features, performance, electrical
characteristics, ratings, and finishes.
B. Shop Drawings: Detail assemblies of standard
components that are custom assembled for specific
application on this Project.
1. Functional Block Diagram:
Show single-line interconnections between
components including interconnections
between components specified in this Section
and those furnished under other Sections.
Indicate methods used to achieve systems
integration. Indicate control, signal, and
data communication paths and identify
programmable logic controllers, networks and
control interface devices and media to be
used. Describe characteristics of network
and other data communication lines.
2. Raceway Riser Diagrams:
Detail raceway runs required for access
control, intrusion detection intercom and
for systems integration. Include designation
of devices connected by raceway, raceway