Bosch K2200 Series Guide de l'utilisateur Page 50

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 62
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 49
K2200 Series | User Guide | 6.0 Installer Commands EN | 50
Bosch Security Systems | 7/03 | 17376 v1.1 / 47491C
To program the door controller relays, select DR 4,
DR 8, DR 12, DR 16 for door controllers 1, 2, 3 and
4 respectively, provided no alarm modules are
installed on these channels.
1. Present an editor key to the faceplate reader.
2. Enter the password and press [ENT], if required.
3. You will now see the CMD prompt.
4. Type [R][E] and press [ENT].
CMD RE_
5. Door 1, Relay 1 Time Profile Number - Enter
a time profile number (1-128). When the time
profile is activated, the relay will activate; when
the time profile finishes, the relay will deactivate.
A time profile of 0 will remove any timed
activation.
DR 1 RLY 1 TP 0
Press the [ENT] key.
Press [NXT] to go to the next field.
6. Door 1, Relay 1 System Event - Enter a system
event (0-15) as shown in the table above.
DR 1 RLY 1 SYS 0
Press the [ENT] key.
Press [NXT] to go to the next relay.
There are a total of 4 relays, each with a time
profile and system event value.
Press [ESC] to return to the CMD prompt.
Examples
To have each door controller use its four on-board
relays to indicate Door Left Open for its own
individual doors:
1. Use the RE command and select the DR 4
record for door controller 1.
2. For RLY1 SYS enter a value of 4 and press
[ENT].
3. For RLY2 SYS enter a value of 5 and press
[ENT].
4. For RLY3 SYS enter a value of 6 and press
[ENT].
5. For RLY4 SYS enter a value of 7 and press
[ENT].
If door 2 is left open relay 2 will activate and stay
activated until the door is closed.
Vue de la page 49
1 2 ... 45 46 47 48 49 50 51 52 53 54 55 ... 61 62

Commentaires sur ces manuels

Pas de commentaire