To test individual detection devices, simply activate
sensors and open protected doors and windows one-at-
a-time. As you fault each detection device, the keypad
from which you initiated the test emits a brief tone, and
for 60 seconds the display indicates that the point was
tested. The tone and display verify that each detection
device is working properly. Keypads within the area’s
scope from which you did not initiate the walk test
show Walk test in progress during the testing.
Performing a walk test:
1. Press [MENU] to open the Main menu.
2. Use [NEXT] to go to the Actions menu option, and
press [ENTER], or simply press [3].
3. Use [NEXT] to go to the Test menu option, and press
[ENTER], or simply press [3].
4. Press [1] or [ENTER] to open the Walk Test menu.
5. Enter your passcode and press [ENTER].
6. Use [NEXT] to go to the desired walk test, and press
[ENTER], or simply press the number key for the
desired walk test: [1] for Fire, [2] for Intrusion, [3]
for Service, or [4] for Invisible.
7. Press [ENTER] to view the points.
8. Use [NEXT] to toggle through your desired point and
view the status of that point.
9. Press [ESC] to exit the menu.