Figure 4.3: Mounting the module to the exterior wall of the enclosure
Callout Description
1 B450
2 Enclosure (outside wall shown)
3 Mounting screws (3 screws included)
Installing in a control panel enclosure
Install the B450 on the inside enclosure wall that also contains the supported control panel.
The control panel powers the B450 via the terminal block or bus connection.
Installing in a separate enclosure
Install the B450 on the inside wall of a separate enclosure. The control panel in a nearby,
separate enclosure powers the B450 via the terminal block or bus connection.
Installing in a separate enclosure with separate power supply
Install the B450 on the inside wall of a separate enclosure that also has a separate external
power supply such as the B520 Auxiliary Power Supply Module.
Mount and wire the tamper switch (option for SDI2 bus only)
You can connect an enclosure door tamper switch for one module in an enclosure.
Installing the optional tamper switch for use with a B450:
1. Mount the tamper switch into the enclosure’s tamper switch mounting location.
2. Plug the tamper switch wire onto the module’s tamper switch connector. For the tamper
switch connector location, refer to Module overview, page 7.
3. Verify the B450 module is configured with tamper enabled ON within the SDI2 supported
control panel. Tamper is automatically enabled to ON in GV4 Series v2.00 control panels.
Install and mount the plug-in communicator antenna
Perform the following steps below to install and mount the magnetic antenna.
4.3.1
4.4
12 en | Installation
Conettix Plug-in Communicator
Interface
2013.09 | 02 | F.01U.282.875 Installation and Operation Guide Bosch Security Systems, Inc.