10 Reporting Format Definitions
Modem IIIa
2
Event Modem IIIa
2
Code
D6500 Mode
Modem IIIa
2
Code
Bosch SIA Mode
Contact ID Event Contact ID
Code
A point supervisory
condition occurred
Jsppp NriaBSppp 24 hour Non-Burglary 1 150 00 000
A valid local access
occurred
RsF01 NLS Successful Download/Access 1 412 00 000
A valid remote access
callback occurred
RsssF NphhhRS Successful Download/Access 1 412 00 000
A valid remote access
occurred
RsssF NRS Successful Download/Access 1 412 00 000
AC Fail – mains power
supply
Pssss NAT AC Loss 1 301 00 000
AC Restore – mains
power supply
Rsss0 NAR AC Loss 3 301 00 000
Access Denied – Door
Secured
ADsppp Nria/idiiiDZppp or
Nria/idiii/
ssxDZppp
Access Denied 1 421 aa uuu
Access Denied –
Interlocked
ADsppp Nria/idiiiDWppp or
Nria/idiii/
ssxDWppp
Access Denied 1 421 aa uuu
Access Denied – No rights
in area by card
ADsppp Nria/idiiiDVppp or
Nria/idiii/
ssxDVppp
Access Denied 1 421 aa uuu
Access Denied – Unknown
ID
ADsppp NriaDDppp Access Denied 1 421 aa uuu
Access Granted AGsppp Nria/idiiiDGppp or
Nria/idiii/
ssxDGppp
Access Report by User 1 422 aa uuu
Alarm Asppp NriaBAppp Burglary 1 130 aa ppp
Alarm Cross Point Asppp NriaBMppp Burglary 1 130 aa ppp
Alarm Exit Error Asppp Nria/idiiiEAppp Entry/Exit 1 134 aa ppp
Alarm with Recent Closing Asppp Nria/CRppp Entry/Exit 1 459 aa uuu
All SDI devices are
missing, power is shorted
TsssD NpidddET Expansion Module Failure 1 333 00 000
All SDI devices are
restored, power is normal
RsssD NpidddER Expansion Module Failure 3 333 00 000
An individual SDI device is
missing.
TsssD NpidddEM Expansion Module Failure 1 333 00 000
An individual SDI device is
restored.
RsssD NpidddEN Expansion Module Failure 3 333 00 000
An invalid remote access
callback occurred
TsssF NphhhRU Unsuccessful Access 1 413 00 000
An invalid remote access
occurred
TsssF NRU Unsuccessful Access 1 413 00 000
Armed perimeter delay Csiii Nria/idiiiNL Armed STAY 3 441 aa uuu
Armed perimeter instant Csiii Nria/idiiiNL Armed STAY 3 441 aa uuu
Bypass by Remote Nsppp NriaUBppp Zone/Sensor Bypass 1 570 aa ppp
Bypass by SDI device Nsppp Nria/pidddUBppp Zone/Sensor Bypass 1 570 aa ppp
Bypass by Sked Nsppp Nria/aikkkUBppp Zone/Sensor Bypass 1 570 aa ppp
Bypass by User Nsppp Nria/idiiiUBppp Zone/Sensor Bypass 1 570 aa ppp
Bypass Point Nsppp NriaUBppp Zone/Sensor Bypass 1 570 aa ppp