Bosch DVR-16K Guide d'installation Page 21

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 20
RAID Subsystem DVA-08K and DVA-16K | Quick Installation Guide Connecting a Digital Video Recorder | en 21
Bosch Security Systems F.01U.027.800 | V1 | 2006.05
12.2 Connecting a Divar
The following hardware is required to connect a Divar:
To connect a Divar with the first subsystem you need the DVA-ACON-HD50A SCSI cable.
To expand an existing system (Divar and subsystem) with an additional subsystem, you
must order the DVA-ACON-VD680A (0.5 m/20 in.) SCSI cable.
To connect the Divar:
1. Connect the Divar with the subsystem. You must switch the Divar and the subsystem off.
Take care of proper connection and tighten the screws of the plug.
Fig. 12.2 Connecting Divar
2. For daisy chaining several subsystems, you must switch off the termination of channel
CH0/1-OUT of all subsystems except the last.
Expand the configuration tree -> click Configuration -> Channel -> Channel 0 or
Channel 1 -> ID Tab -> Termination: Disabled -> Apply.
3. Click Configuration -> Configuration Parameters -> System tab -> Reset the Controller -
> Apply. The subsystem is reset.
4. For daisy chaining, change the CH0/1-OUT SCSI channel ID of the second subsystem.
Expand the configuration tree -> click Configuration -> Channel -> Channel 0 or
Channel 1 -> Parameters Tab -> for DVA-08K: clear the 0 and 1 check boxes and select
the 2 and 3 check boxes -> Apply.
5. Click Configuration -> Configuration Parameters -> System tab -> Reset the Controller -
> Apply. The subsystem is reset.
6. Click Configuration -> Host LUN Mapping and change to new ID.
7. Switch on the subsystem and then the Divar. The power switches of the subsystem are
located on the rear side of the unit.
To configure the Divar:
(Use the control elements on the front panel)
i
NOTICE!
Two subsystems: Make the SCSI connection after you have changed the SCSI ID of the
second subsystem.
Due to SCSI specifications, do not daisy chain more than two subsystems.
CAUTION!
The internal disks of a Divar must be disabled when using a disk array in RAID mode. Oth-
erwise if the internal disk of Divar fails, all data is lost (even on the subsystem).
1 Divar 5 CH0-OUT
2 RAID subsystem 6 DVA-ACON-HD50A SCSI cable
3 SCSI port 7 DVA-ACON-VD680A SCSI cable
4 CH0-IN
Vue de la page 20