Engineered Solutions | D9210B Series Access Control Interface Modules
D9210B Series Access Control Interface
Modules
www.boschsecurity.com
u Provides direct interface to 26‑bit Wiegand card
readers
u Onboard buzzer output
u Removable onboard relay for switching
12/24 VDC/VAC power
u Option to unlock or lock door upon SDI bus failure
u Supervised onboard point
The D9210B Access Control Interface Module Series
includes the D9210B and the D9210BLC. The modules
are fully supervised, addressable SDI bus devices that
allow access control integration for the Bosch Security
System, Inc. G Series Control Panels. These highly
reliable modules offer 14 programmable levels of
access authority. Authority for access is controlled by
the level of the user, the time of day, the state of the
door and the armed state of the area. Each of the
authority restrictions can be controlled through
automatic and manual functions. Users can be added
to the system with local programming using the
D5200, remote programming using the Remote
Programming Software, or with tokens using the Add
User function through the command center(s).
Functions
Inputs and Outputs
SDI input and output: SDI A (yellow) receives data
from the SDI A of the panel. The SDI B (green)
returns data to the SDI B of the panel.
The 12 VDC input: Powers the D9210B and provides a
connection for the 12 VDC reader and 12 VDC buzzer.
A supervised zone input for the door contact is
physically mounted on the door to which the strike is
connected. The input can be configured for shorts/
opens on faults but is normal only when the 1000 kΩ
resistor is in the circuit.
The unsupervised tamper input is normal when open.
Upon a short, the point number assigned to the
supervised zone is reported as a MISSING PT###
report.
The unsupervised Request to Enter (RTE) and
Request to Exit (REX) inputs are Normally open and
share the same common terminal. The REX input
generates the Door Request to Exit and is used to exit
the area assigned to the D9210B without having to
use an ID. The RTE generates the Door Request to
Enter and is used to enter the area assigned to a
D9210B Series module. Programming REX Shunt Only
and RTE Shunt Only eliminates the need for a strike
and would be used in applications where a push bar
is used to open the door.
The Wiegand reader input is a 5‑wire input that
supplies +5 VDC (use the +12 VDC terminal for 12‑volt
readers), negative, ground activation for the reader
LED, (D1) and (D0) inputs for the card data.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 -

Engineered Solutions | D9210B Series Access Control Interface ModulesD9210B Series Access Control InterfaceModules www.boschsecurity.com

Page 2

• When a door is held open past the normal doorsequence time, an extended door sequence time isinitiated. This extended time extends the shunt andre-a

Page 3

Technical specificationsAlarm InputsDoor Contact Status 1 normally‑closedRequest to Enter (RTE) andRequest to Exit (REX)1 normally‑openV in < 1.8 V

Page 4

4 | D9210B Series Access Control Interface ModulesRepresented by:Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:Bosch Secu